Syringe Pump
M640 Single Channel Syringe Pump
- Brand: Medshine
- Model No.: M640
- Certificate: CE,ISO
- Warranty:12 months
- Product description: A syringe pump is a pump used to deliver precise and accurate amounts of fluid in high-impact research environments ranging in fields from chemistry to neuroscience.
M640 Single Channel Syringe Pump
Features:
1.Compatible with universal standard syringe of 5,10,20,30,50(60)ml
2.High accuracy of ±2% after correct calibration
3.Automatically detect the syringe size
4.Three working modes: Rate Mode, Time Mode, Body-weight Mode
5.Drug library with more than 25 drug names inside pumps
6.4 hours continuous work when battery fully-charged
7.Purge/ bolus function, adjustable bolus rate while pump is infusing
8.Large 4.3 inch color screen, long-distance visibility
9.DPS dynamic pressure display, with three levels of occlusion: Low, Middle, High
10.Visible and audible alarm function to safeguard the infusion
11.KVO function: When finish the total volume of an infusion, the pump will alarm and enter KVO state.
Technical Specifications of Syringe Pump M640
PARAMETER |
SPECIFICATION |
Applicable syringes |
5ml, 10ml, 20ml, 30ml, 50ml, 60ml of any standard syringes |
Accuracy |
±2% with correct calibration |
Rate Mode |
50(60)ml syringe: 0.1-1500.0ml/h (0.1ml/h step) 30ml syringe: 0.1-600.0ml/h (0.1ml/h step) 20ml syringe: 0.1-400.0ml/h (0.1ml/h step) 10ml syringe: 0.1-200.0ml/h (0.1ml/h step) 5ml (2/3ml) syringe: 0.1-100.0ml/h (0.1ml/h step) |
Time Mode |
SOL.VOL:0.1-999.9ml (0.1 ml step) Time:1-2000min (1 min step) |
Preset Time Range: |
0-99 hour, 59 minutes |
Body Weight Mode |
Volume: 0.1-999.9ml(0.1ml step) Drug Mass: 0.1-999.9mg (0.1mg step) Dose: 0.001-9999.9ug/kg/min(0.01ug/kg/min step) (Unit: ug/kg/min, mg/kg/h) Weight: 0.1-300KG(0.1kg the least step) |
Total Volume Range |
0.1-9999.9ml |
Target Volume Range |
0.1-9999.9ml |
Purge/Bolus Rate |
50ml(60ml): 400-1500.0ml/h 30ml: 400-600.0ml/h, 20ml:400ml/h 10ml: 200ml/h, 5ml: 100 ml/h Programmable and adjustable |
KVO Rate |
0.1~5.0 ml/h or the last delivery rate when it is smaller |
Occlusion pressure |
Three level setting LOW, MEDIUM & HIGH |
Alarms |
Near empty, Empty, Occlusion, Over, Syringe Disengaged, Low battery, Wrong parameter, device failures. |
Bolus Volume |
Range:1.0-50.0ml, Increment:0.1ml |
History Records |
(Optional Function) |
Drug Names |
More than 70 drug names contains Penicillin, Vancomycin, Pitocin, Insulin etc (Optional Function) |
Power source |
AC power supply: AC 100 to 240V( +/-10%),50/60Hz; Built-in Lithium Battery: Rechargeable, 7.4V, 3000mAh. 4 hours of continuous operation when infusing at 25 ml/h |
Max Power Consumption |
25 VA |
Accessories: |
AC power cable, Operational manual |
Protection Class |
Class II, Type BF,IPX4 |
Dimension /N.W |
300mm*139mm*100mm , 1.7kg |
Categories
Latest News
- M125 Sperm Analyzer used in German2023-03-30
- Semen Analysis2019-09-04
- Sperm Analyzer Installed in Nigeri2016-01-09
- 4D Color Doppler Ultrasound Machin2019-09-21
- Sperm Analyzer in Iraq Clinic2019-10-12
Contact Us
Contact: Mr. Xu
Phone: +86 15862141558
Tel: +86 15862141558
Whatsapp: Medshine
Email: medshine@medshinegroup.com
Add: Jiangsu Province, China