M642 Double Channel Syringe Pump
- Brand: Medshine
- Model No.: M642
- Certificate: CE,ISO
- Warranty:18 months
- Product description: double channel syringe pump is our basic two channels syringe pump.Two syringe pumps allows injection with different flow rates and two colors design make it easy to distinct.
M642 Double Channel Syringe Pump
Features of Dual Channel Syringe Pump
1. HD LCD Display, high capacity words, friendly user interface, dynamically display working status;
2. Visual alarm for occlusion, empty, near empty, low battery, end of infusion, syringe loose, wrong setting, etc.;
3.The syringe pump can be operated separately and compatible with 5ml, 10ml, 20ml, 30ml, 50/60ml syringe of any brands;
4. Preset solution volume to greatly reduce the workload of nurses;
5. Three working modes: Rate Amode, Time Volume mode, Dosage Weight mode;
6. Three levels of occlusion: high, medium and low;
7. Purge and Bolus function;
8.KVO(keep-vein-open) automatically opens as injection is completed, KVO rate is 1ml/h;
9. Power Source: AC100---240V, 50/60Hz; Internal Battery, DC12V car charge;
10. One-key operation makes setup easy and simple;
11. Syringe plunger grabble detector, operable with one hand in a No-Germ Environment;
12. Automatically record the settings of last injection;
13. OEM is available.
Specification of Dual Channel Syringe Pump
Rate |
50/60ml Syringe: 0.1ml/h ~ 999.9ml/h (0.1ml/h step) |
Flow Rate Accuracy |
Within ±3% (after correct calibration) |
Mechanical precision |
Within ±2% |
Bolus Rate |
50/60ml Syringe: 1,200ml/h |
Purge Rate |
50/60ml Syringe: 1,500ml/h |
Volume Limit |
0.1ml ~ 9999.9ml(0.1ml step) |
Total Injection |
0.1ml ~ 9999.9ml (0.1ml step) |
Occlusion of Dual Channel Syringe Pump |
High: 800mmHg ±200mmHg (106.7kPa±26.7kPa |
Alarms |
Injection soon finish, end of injection,occlusion, improperly installation of syringe, wrong setting, low battery, syringe loose etc. |
Power Source |
AC 100V ~ 240V, 50/60Hz; Internal rechargeable Li battery, capacity≥1,600mAh, 4 hours internal battery backup |
KVO rate |
1ml/h |
Fuse |
F1AL/250/60V, 2pcs inside |
Power Consumption |
30VA |
IP Classification |
IPX4 |
Equipment Classification |
Class II, internal power supply, Type CF |
Operating Condition |
Ambient temperature: +5℃~ +40℃ |
Relative humidity |
20 ~ 90% |
Transport & Storage Condition |
Ambient temperature:-30℃~ +55℃ |
Relative humidity |
≤95% |
Dimension |
280mm (L) ×210mm(W) ×130mm(H) |
Weight |
3.6kg (net weight) |
Categories
Latest News
- M125 Sperm Analyzer used in German2023-03-30
- Semen Analysis2019-09-04
- Sperm Analyzer Installed in Nigeri2016-01-09
- 4D Color Doppler Ultrasound Machin2019-09-21
- Sperm Analyzer in Iraq Clinic2019-10-12
Contact Us
Contact: Mr. Xu
Phone: +86 15862141558
Tel: +86 15862141558
Whatsapp: Medshine
Email: medshine@medshinegroup.com
Add: Jiangsu Province, China